RPS trips occur on what?
RPS alarms occur on what?
Trips
Alarms
What is the Variable High Power Trip?
Protects against positive reactivity excursions during power operation and while shutdown.
From TMM Variable High Power Output
What is the high power rate trip?
High Power Rate Trip
Protects against an uncontrolled rod withdrawal or boron dilution incident while the reactor is critical but at low power levels
Only when power is greater than 10-4 % and less than 15%
From WR NI’s
Trip
Pretrip
What is the Low Reactor Coolant Flow Trip?
Low Reactor Coolant Flow Trip
Protects against fuel damage on loss of coolant flow. (DNB)
Trip
Pretrip
What is the A/B Steam Generator Low Level Trip?
Steam Generator Low Level Trip
Protects against loss of heat removal capability from the primary coolant system.
Trip
Pretrip
What is the A/B Steam Generator Low Pressure Trip?
Steam Generator Low Pressure Trip
Protects against excessively high steam flow caused by a steam line break.
Trip
Pretrip
What is the Pressurizer High Pressure Trip?
Pressurizer High Pressure Trip
Prevents operation when the reactor is generating more power than the secondary system is accepting .
Trip
Pretrip
What is the TM/LP Trip?
TM/LP Trip
Prevent the violation of minimum Departure from Nucleate Boiling Ratio.
Trip
Pretrip
What is the Loss of Load Trip?
Loss of Load Trip
Limits the primary coolant system stored energy and pressure caused by the suspension of normal steam removal. (prevents lifting Pressurizer/main steam safety valves)
Set point
What is the Containment High Pressure Trip?
Containment High Pressure Trip
Provides an earlier action than would be available with only the thermal margin low pressure trip or the steam generator pressure trip.
Was added to the RPS to provide diversity of reactor trip for the loss of coolant
accident.
Set point
Pre-Trip at 3.4#
Pre-trip has no alarm, illuminates white light on auxiliary trip unit
EK0917, “ROD WITHDRAWAL PROHIBIT”
EK0917, “ROD WITHDRAWAL PROHIBIT”
Trip Setpoints:
Variable High Power Pre-Trip (2 of 4):
Minimum: 28.5%
Variable: 13.5% above reset power level
Maximum: 105%
or
High Power Rate Pre-Trip (1 of 4) at 1.5DPM (effective 10-4 to 15%
power)
or
Removal/Failure of RPS Bistable
High Power Rate Pre-Trip/Trip (1 of 4) at less than 15% power
or
EM OFF