What is purpose of SDC?
Removes PCS decay heat during Rx shutdown. Transfers heat from PCS to CCW
Cool PCS from 300°F to refueling temp assuming CCW inlet temperature of 90°F
What are SDC design limits?
300°F
270 psia.
SDC Hxs will cool the PCS to 130°F and maintain it at 130°F 27 ½ hours after reactor shutdown with 90°F CCW temperature and a fully irradiated core
Draw and label a one-line diagram of the Shutdown Cooling System showing system interfaces and the following major components:
Draw
Describe power supplies, controls and interlocks for MO-3015/3016.
Controls
Power Supplies
Interlocks
What is the basis for the procedural limitations / interlocks on opening MO-3015/3016?
Set to not violate the equipment limitations.
What is required on SDC to protect agains over pressure?
With the PCS pressurized, what limitations are on MO-3015/3016 operating ability if already open?
When the PCS is pressurized AND MO-3015 and MO‑3016 are OPEN, THEN power shall be maintained to at least one of the two valves. This prevents an unisolable PCS leak if RV-3164 fails open.
What is purpose, setpoint and relief path of RV-0401?
RV-0401
Setpoint: 2485 psig
Relieves to the PSDT, T-74
What is purpose, setpoint and relief path of RV-0402/0403?
RV‑0402 and RV‑0403
What is purpose, setpoint and relief path of RV-03164, SDC Suction Relief?
RV-3164 SDC Suction Relief
What are the LPSI Pumps Inlets from SIRWT Valves?
What are the LPSI Pumps Inlets from SDC Valves?
MO-3190 (P-67B suction from PCS)
MO-3199 (P-67A suction from PCS)
What are the LPSI pump specs?
Single Stage, Horizontal, Centrifugal
3,000 gpm
o Maximum Flow - 4,500 gpm
o Minimum Flow - 163 gpm
· Design Head - 350 ft
o Shutoff Head - 410 ft
· Horsepower - 400
· Seals - Mechanical
· NPSH Required at 3,000 gpm - 11 ft
Maximum Normal Suction Pressure - 270 psia